    Dualstream Technical Specification - Accumulator


The accumulator dimensions


The accumulator parts

Dualstream is protected by Patent No. 9905894.3 this protection applies to the use of any accumulator with any unvented cylinder and the application of its use subject to permission being obtained form GAH (HEATING PRODUCTS) LIMITED WRAS Certificate No. 0109003.

This unique range of accumulators feature a patented controlled action diaphragm with special diffuser to prevent stratification.

  • Maximum working pressure 10 bar (shell)
  • Maximum operating temperature 70c
  • Pre-charge pressure should be set at 1.5 bar below mains static pressure, minimum pre-charge pressure 0.5 bar. This should be carried out before the accumulator is connected to the system
  • The accumulator will hold approximately half its total volume in mainss water at mains pressure
Accumulator size (litres)
Diameter
Height
Nett weight (kg)
Connection size
80 ltr*
410mm
730mm
16.3
1"
170 ltr*
535mm
920mm
30.4
1"
240 ltr
535mm
1215mm
37.2
1"
310 ltr*
535mm
1575mm
44.5
1"
450 ltr*
668mm
1575mm
69.5
1"
*Sizes used with standard systems
Option on 200-125, 150 or 210 hot water cylinders

 

Dualstream Technical Specification - Accumulator
Cylinder size 125-300 Ltr
Cylinder dimensions
Direct
Cylinder size 125-300 Ltr
Cylinder dimensions
Indirect

Indirect and Direct Unvented Cylinders

  • Quality steel tank tested to 12 bar
  • Exclusive vitreous enamel coating
  • CFC free polyurethane thermal insulation
  • All plumbing connections within a 90º angle
  • Unique coil allows full quantity of water to be heated
  • Slimmest design available on the market
  • Secondary return connection on all models
Cylinder size 500 Ltr
Cylinder dimensions
Direct
Cylinder size 500 Ltr
Cylinder dimensions
Indirect
Model Storage Capacity Units pipe size inlet outlet Coil surface m² Coil rating Reheat time (t=50c) Element power Max temp.
A
B
C
D
E
F
G
Nett weight (kg)
DIRECT RANGE
Contract STD 125 125 ltr 3/4"     150 min 3kw+3kw 70c 650 755 995   505 265 225 33
Contract STD 150 150 ltr 3/4"     175 min 3kw+3kw 70c 790 915 1155   505  265  225  40
Contract STD 210 200 ltr 3/4"     240 min 3kw+3kw 70c 940 1230 1475   505  265  225  45
Contract STD 300 300 ltr 3/4"     350 min 3kw+3kw 70c 1215 1555 1790   560 275 255 85
500 STD UK 495 ltr 1"     290 min 6kw 70c 1390 335 1870   714     130
INDIRECT RANGE 
Contract STI 125 125 ltr 3/4" 0.75 20.5kw 18 min 3kw 70c 650 755 995 625 505 265 225 41
Contract STI 150 150 ltr 3/4" 0.9 26.7kw 22 min 3kw 70c 790 915 1155 765 505  265  225  51
Contract STI 210 200 ltr 3/4" 0.9  26.7kw  26 min 3kw 70c 940 1230 1475 765 505  265  225  56
Contract STI 300 300 ltr 3/4" 0.9  26.7kw  40 min 3kw 70c 1215 1555 1790 815 560 275 255 95
500 STI UK 495 ltr 1" 1.5 31.8kw 54 min 6kw 70c 1390 335 1870 700 714     149

Each Dualstream system is supplied with a comprehensive illustrated manual, which takes you through the installation process.

To speed up installation time each Dualstream system has a factory fitted copper framework including the following components:

  • Combination valve (3.5 bar pre-set pressure reducing valve), line strainer, check valve and expansion vessel connection point.
  • The framework includes expansion valve discharge to the tundish linked to the discharge pipe form the 1/2" temperature and pressure relief valve.
  • The 3kw immersion heater is fitted (indirect models only) complete with regulation thermostat, dual pole thermal cut out, (2.3kw immersion heaters on direct models). ProTech anti corrosion systems o models up to 300 ltr.
  • A two port motorised valve supplied to be installed on a 'S' plan system (indirect models only).

In addition all Dualstream systems are supplied with one 22mm double check valve and three 22mm full bore lever valves.

 

Unique Concept...
GAH Unrivalled Performance
About Dualstream | Choosing Your System | Technical Info | Contact Us | Company Profile | Home