V V
Choosing Your System
Home to Dualstream
Home to GAH Group
Choosing your Dualstream system


To obtain the very best performance from your Dualstream system the accumulator must be sized correctly, as it is the driving force supplying hot and cold similtaneous demand to the building.

The accumulator will hold approximately half its total volume and we would recommend a recovery time of 15 minutes, this will depend on the flow rate from the main supply, which can vary.

When choosing your Dualstream, consider the following:


  • Mains flow rate and static pressure
  • House type and number of occupants
  • Typical daily water usage
  • Number of bathrooms/ensuite/showers
  • Other water usage hot or cold
1>

 


House 1

 

 

2>

House 2

 

3>

House 3

Ref no Guide to hot water demand Direct model Indirect model
1
1 bed, 2 people, bath + shower, kitchen TDD/C 80/125 TDI/C 80/125
1
2 bed, 3 people, bath + shower, kitchen TDD 200 or 125/150 TDI 200-125/150
2
3 bed, 4 people, bath + shower, kitchen TDD 200 or 300/150/210 TDI 200 or 300-150/210
2
4 bed, 5 people, 2 baths + shower, kitchen TDD 200 or 300/210 or 300 TDI 200 or 300/210 or 300
3
Larger homes TDD 300 or 500/300 or 500 TDI 300 or 500/300 or 500
  Small commercial TDD 500/500 TDI 500/500

For example
Model number TDI 500/300 has a 500 ltr accumulator with a 300 ltr indirect cylinder. Two or more models can be installed in parallel for greater volume demand.
Professional design service available.

 

 

Unique Concept...
GAH Unrivalled Performance
About Dualstream | Choosing Your System | Technical Info | Contact Us | Company Profile | Home